Test #02-003, P-100 Pump Deep Water Dewatering Exercise on Scaffolding on DCETF

DAMAGE CONTROL ENGINEERING TEST FACILITY

(DCETF)
NAVAL RESERVE CENTER, BALTIMORE
TEST DATA

TEST NUMBER: 02-003 DATE: 26 July 2001
Set-Up 24- 25 July 2001
TEST TITLE: P-100 Pump deep water dewatering exercise on scaffolding on DCETF
OBJECTIVE / Test set-up criteria: Dewatered flooded compartment using P-100 Pump rigged with suction and discharge hoses from greater than 20 ft suction distance. For each Test, compartment B-1 was filled with about 5 6 of water equal to 1320 gallons and left with 1' (240gal.) of water for a total of 1080 gallons pumped.
DESCRIPTION OF TEST - RESULTS: TEST NO. 1: Dewatered flooded space using P-100 rigged with standard foot valve from a height of 30 feet. Pump was primed repeatedly without success. Could not draw a suction
EVALUATION: U.S. COAST GUARD P-100 Pump
TEST TEAM:
webmaster@dcfpnavymil.org, NAVSEA 05L4
Dennis McCrory, NAVSEA 05L4
Dexter Vance, CSC
Creig Beck, NAVSEA
EQUIPMENT NAME: W.S. Darley KIWI EDUCTOR
EQUIPMENT MANUFACTURER: W.S. Darley Pump Company
PHONE: 1-800-323-0244 Paul Darley
RECOMMENDATIONS: Above 20 feet, P100 will require two P100s to be run in tandem.